Oxygen concentration meter(1 ppm) - List of Manufacturers, Suppliers, Companies and Products

Oxygen concentration meter Product List

1~5 item / All 5 items

Displayed results

Pump-integrated oxygen concentration meter unit TKZH007, for glove box use only.

Oxygen concentration meter side unit for glove box exclusive model.

● Dedicated model for glove boxes ● Galvanic type resistant to combustible gases and organic solvents ● Choose from PPM model or % model ● Minimal leakage due to ALLSUS piping inside the device ● Excellent operability and maintainability ■ This unit can measure oxygen concentration at ppm or % levels according to the application. It has a built-in flow meter, needle valve, and pump, allowing for easy measurement of ppm level oxygen concentration by simply connecting to the sample IN/OUT. For more details, please download the catalog or contact us.

  • Other measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Galvani-type battery panel mount Model 201RS/2001RS

Oxygen concentration meter powered by a galvanic battery, resistant to combustible gases and organic solvents, capable of measuring at % and PPM levels.

● Measurement at % and PPM levels ● Galvanic battery-type sensor resistant to combustible gases and organic solvents ● Unique patented sensor with high response speed, long lifespan, and disposable design ● Standard equipment includes sampling system and solenoid valve ● Real-time data management via computer ● Data logging function ■ Model 2001RS is an oxygen analyzer capable of measuring from 0 to 10,000 ppm. Model 201RS is an oxygen analyzer capable of measuring from 0.1% to 25%. ■ All operations, including setting the output range, configuring two alarm points, and changing the span during calibration, can be performed from the front panel without removing the oxygen meter from the panel. Additionally, the sensor is designed as a disposable cartridge, allowing for easy manual replacement from the front panel. For more details, please download the catalog or contact us.

  • Other analytical equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Pump-integrated oxygen concentration meter unit TKZH006

All sampling equipment is built-in, completing oxygen measurement with just one device!

■ Ideal for spot checks ■ Simple operability ■ Choose from PPM model or % model ■ For measuring atmosphere in furnaces ■ For measuring atmosphere in tanks This product is an all-in-one portable oxygen meter equipped with necessary sampling equipment for oxygen measurement. It includes a filter, pump, needle valve (built into the oxygen meter), flow meter (built into the oxygen meter), a ball valve for sealing the oxygen sensor, and a bypass line. This allows for complete oxygen measurement in general environments. Additionally, for applications with a lot of dust, an external pre-filter is available as an option. The oxygen concentration meter is equipped with the AMI galvanic battery-operated oxygen meters 2001LC (for ppm measurement) or 201LC (for % measurement), which are well-regarded for measuring oxygen in furnaces. For more details, please download the catalog.

  • Other measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

The principle of an oxygen concentration meter.

Principle of Galvanic Battery Type/Zirconia Type Oxygen Concentration Meter

In Tekune Measurement, we handle two types of oxygen concentration meters based on the principles of galvanic cell and zirconia methods. 〇 Galvanic Cell Type The lead anode performs an oxidation reaction, assisting the reduction reaction at the cathode. It behaves as if combustion is occurring at the anode due to oxygen, generating current, which is why it is also called a fuel cell type. PPM models: 2010BX, 2001RS, 2001LC, 1000RS % models: 210BX, Oxtron, 201RS, 1100BE, 201LC 〇 Zirconia Type It compares an unknown process gas with a known reference gas using the Nernst equation. The sensor measures the electromotive force to determine the oxygen concentration. Examples of PPM models: 4100, 7100, etc. Examples of % models: 111, 5100, etc. For more details on the principles of oxygen concentration measurement, please refer to the URL below.

  • Other measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

What is an oxygen concentration meter?

Introducing recommended products based on usage purpose and measurement range!

Here is an introduction on how to choose an oxygen concentration meter. An oxygen concentration meter (O2 meter, Oxygen Analyzer) should be selected based on its intended use and measurement range. Oxygen concentration meters are used to check the concentration of oxygen in medical, personal, and industrial applications. There are various methods for selecting an oxygen concentration meter. Considerations include the gases that can be measured, measurement range, accuracy, installation environment, maintenance, price, and intended use (medical, personal, manufacturing, etc.). Choose the appropriate type to select an oxygen concentration meter that fits the usage location. When selecting an oxygen concentration meter, it is important to consider the following points: - Choose based on the gases that the oxygen concentration meter can measure. - Choose based on the measurement range of the oxygen concentration meter. - Choose based on the measurement accuracy (ppm, ppb, etc.) of the oxygen concentration meter. - Choose between portable or fixed installation for the oxygen concentration meter. - Choose based on the output of the oxygen concentration meter. - Choose based on the installation environment of the oxygen concentration meter. - Choose based on maintenance requirements for the oxygen concentration meter. - Choose based on price for the oxygen concentration meter. - Choose based on the intended use of the oxygen concentration meter. - Choose a type suitable for the application of the oxygen concentration meter. Please check the website below for more information.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration